Koldlok SwitchFix – SF001-PR3
switchfix-sf001-pr3-passive-blanking-panel

Koldlok SwitchFix – SF001-PR3

Network switch equipment typically sits at the top and back portion of the server rack. This placement makes it difficult for cold air from the cold aisle to travel from the front of the rack to the intake side(s) of the Network Switch. Koldlok The SwitchFix solves this problem by extending from the front of the rack in the cold aisle to the switch at the back of the rack. This allows cold air from the cold aisle to reach the network equipment for proper cooling

The Koldlok SwitchFix comes in a variety of sizes to meet the needs of many switches currently used in today’s data centers. Each unit adjusts in depth to ensure an optimal flow of cooled air through to the installed switch. The SwitchFix easily accommodates front, rear, and side switch intakes and exhaust. The SwitchFix’s passive airflow system channels air from the cold aisle to the switch, allowing cold air to pass through the switch intakes and prevents bypass and recirculated airflow. This prevents hot exhaust air from recycling through the installed equipment. This passive switch cooling solution can improve switch performance and life expectancy.

Which Koldlok SwitchFix should you get? Refer to our SwitchFix Cross Reference Guide.

Koldlok SwitchFix – SF001-PR3

$311.00

Network switch equipment typically sits at the top and back portion of the server rack. This placement makes it difficult for cold air from the cold aisle to travel from the front of the rack to the intake side(s) of the Network Switch. Koldlok The SwitchFix solves this problem by extending from the front of the rack in the cold aisle to the switch at the back of the rack. This allows cold air from the cold aisle to reach the network equipment for proper cooling

The Koldlok SwitchFix comes in a variety of sizes to meet the needs of many switches currently used in today’s data centers. Each unit adjusts in depth to ensure an optimal flow of cooled air through to the installed switch. The SwitchFix easily accommodates front, rear, and side switch intakes and exhaust. The SwitchFix’s passive airflow system channels air from the cold aisle to the switch, allowing cold air to pass through the switch intakes and prevents bypass and recirculated airflow. This prevents hot exhaust air from recycling through the installed equipment. This passive switch cooling solution can improve switch performance and life expectancy.

Which Koldlok SwitchFix should you get? Refer to our SwitchFix Cross Reference Guide.

Request a Quote
Features
  • Channels cold air to the switch
  • Prevents hot air recirculation
  • Maintains cold aisle/hot isle segregation
  • Adjustable for a variety of depths
  • Passive airflow circulation
Specifications
Solution Request

Name (required)

Email Address (required)

Phone Number

Notes/Questions

Accessories
Similar Products
arrow