DCR In-Row Cooling

DCR’s In-Row cooler (IRC) is available in three configurations maximizing the performance consistent with the site infrastructure.

The Open-Loop configuration incorporates all of the controls, display monitoring devices, heat exchange coil and plumbing into each unit. The hot air is collected from the ‘hot aisle’, pulled through the heat exchange coil, and the cooled air is then exhausted into the ‘cold aisle.’
The Closed-Loop configuration incorporates the same features as above except the front and rear doors are solid. The hot air is collected directly from the rear of the server cabinets, pulled through the coils and the cooled air directly exhausted to the fronts of the adjacent server cabinets.
The Self-contained solution is to incorporates both airflow solutions in the same configuration so that the hot air is collected from both the hot aisle and directly from the rear of the servers, and the cold air exhausted both into the cold aisle as well as directly to the fronts of the adjacent servers. This option can be used with fully enclosed cabinets for self-contained cooling pods or rows.

DCR’s In-Row cooler (IRC) is available in three configurations maximizing the performance consistent with the site infrastructure. The Open-Loop configuration incorporates all of the controls, display monitoring devices, heat exchange coil and plumbing into each unit. The hot air is collected from the ‘hot aisle’, pulled through the heat exchange coil, and the cooled air is then exhausted into the ‘cold aisle.’

DCR In-Row Cooling

DCR’s In-Row cooler (IRC) is available in three configurations maximizing the performance consistent with the site infrastructure.

The Open-Loop configuration incorporates all of the controls, display monitoring devices, heat exchange coil and plumbing into each unit. The hot air is collected from the ‘hot aisle’, pulled through the heat exchange coil, and the cooled air is then exhausted into the ‘cold aisle.’
The Closed-Loop configuration incorporates the same features as above except the front and rear doors are solid. The hot air is collected directly from the rear of the server cabinets, pulled through the coils and the cooled air directly exhausted to the fronts of the adjacent server cabinets.
The Self-contained solution is to incorporates both airflow solutions in the same configuration so that the hot air is collected from both the hot aisle and directly from the rear of the servers, and the cold air exhausted both into the cold aisle as well as directly to the fronts of the adjacent servers. This option can be used with fully enclosed cabinets for self-contained cooling pods or rows.

DCR’s In-Row cooler (IRC) is available in three configurations maximizing the performance consistent with the site infrastructure. The Open-Loop configuration incorporates all of the controls, display monitoring devices, heat exchange coil and plumbing into each unit. The hot air is collected from the ‘hot aisle’, pulled through the heat exchange coil, and the cooled air is then exhausted into the ‘cold aisle.’

Category:

Reviews

There are no reviews yet.

Be the first to review “DCR In-Row Cooling”

Request a Quote
Features
  • Nominal 20,000 Watt heat removal (6.4 gpm and 48F inlet water temperature)
  • User-controllable fan speeds
  • Optional automatic transfer switch for dual input power
  • 5 hot-swappable fans
  • Two-way motorized valve for water flow control
  • Settable internal temperature
  • Top or bottom input configurations
  • Remote access via Internet
Specifications
  • Narrow 12” wide footprint
  • Color touchscreen display with array of user defined monitoring and alarms
  • Sized to height and width of server cabinets
  • Five individually replaceable exhaust fans
  • Ideal for cold aisle containment (CAC)

 

DCR In-Row Cooling (IRC) Models
Part # Description Dimensions  

DCR In-Row Cooling (IRC) Module, 20 kW, 42U, 1000mm depth

78.75″H x 12″W x 39.4″D

DCR In-Row Cooling (IRC) Module, 20 kW, 45U, 1000mm depth

84″H x 12″W x 39.4″D

DCR In-Row Cooling (IRC) Module, 20 kW, 47U, 1000mm depth

87.5″H x 12″W x 39.4″D

DCR In-Row Cooling (IRC) Module, 20 kW, 52U, 1000mm depth

96.2″H x 12″W x 39.4″D