DataCenterSales@armstrongceilings.com | 866.740.2121 | Contact Us
cropped-DCR-Transparent-Logo-2.png
  • Cooling
    Optimization
    • Aisle Containment
    • CRAC Hoods
    • Koldlok Floor Grommets
    • High Flow Floor Tiles
    • Ceiling Grid Fan Tray
    • Barrier Panels
    • Blanking Panels
    • Foam Gap Seal
    • Magnetic Cabinet Skirts
  • Aisle
    Containment
    • Aisle Containment Panels
    • Aisle Containment Doors
    • Aisle Containment Flexible Strip Curtains
    • Cool Shield Structure
  • Power
    Management
    • Rack Power Distribution
      • Enconnex PDUs
      • Enconnex Rack Mount PDUs
      • Upsite PowerLok PDUs
    • UPS Systems
      • Rack UPS
      • Scalable UPS
    • Cords and Cables
      • Server Cables & Cords
      • PDU Cables
  • Data Center
    Monitoring
    • Temperature Monitoring
    • Airflow Monitoring
    • Battery Monitoring
  • Server Rack
    Infrastructure
    • Enterprise Server Cabinets
    • Air Conditioned Enclosures
    • RF Shielded Cabinets
    • Data Center Cages
  • Data Center
    Flooring
    • New Access Floor Tiles
    • Replacement Access Floor Tiles
    • Clear Access Floor Tiles
    • Access Floor Tile Accessories
    • Fan Powered Floor Tiles
  • Modular
    Infrastructure
    • Modular Data Center Blocks
    • Edge Aisle Data Center
  • Cooling
    Optimization
    • Aisle Containment
    • CRAC Hoods
    • Koldlok Floor Grommets
    • High Flow Floor Tiles
    • Ceiling Grid Fan Tray
    • Barrier Panels
    • Blanking Panels
    • Foam Gap Seal
    • Magnetic Cabinet Skirts
  • Aisle
    Containment
    • Aisle Containment Panels
    • Aisle Containment Doors
    • Aisle Containment Flexible Strip Curtains
    • Cool Shield Structure
  • Power
    Management
    • Rack Power Distribution
      • Enconnex PDUs
      • Enconnex Rack Mount PDUs
      • Upsite PowerLok PDUs
    • UPS Systems
      • Rack UPS
      • Scalable UPS
    • Cords and Cables
      • Server Cables & Cords
      • PDU Cables
  • Data Center
    Monitoring
    • Temperature Monitoring
    • Airflow Monitoring
    • Battery Monitoring
  • Server Rack
    Infrastructure
    • Enterprise Server Cabinets
    • Air Conditioned Enclosures
    • RF Shielded Cabinets
    • Data Center Cages
  • Data Center
    Flooring
    • New Access Floor Tiles
    • Replacement Access Floor Tiles
    • Clear Access Floor Tiles
    • Access Floor Tile Accessories
    • Fan Powered Floor Tiles
  • Modular
    Infrastructure
    • Modular Data Center Blocks
    • Edge Aisle Data Center
Home / Data Center Flooring / Data Center Floor Grommets / Koldlok 40001
Koldlok 4001 Floor Grommet
Koldlok 4001 Floor Grommet
Koldlok 40001 - Image 3

Koldlok 40001

Categories Koldlok Products, Data Center Floor Grommets

Round 4 inch split integral grommet allow tiles to be moved without capturing cables

Airflow management device designed to seal cable openings in new raised-floor systems prior to the installation of communication/power cabling and seal cable openings in existing raised-floor systems with the flexibility of removing tiles without capturing cables. Sealing the openings in the raised floor prevents cool supply air from escaping where it is not needed. This increases the static pressure in the underfloor plenum to provide higher cooling efficiency.

Benefits
Allows for greater IT density
Increases cooling unit effectiveness
Decreases humidity control expense
Increases static pressure under the raised floor
Improves cool air delivery through perforated tiles
Prerequisite for hot aisle/cold aisle best practices
Reduces the need to purchase additional HVAC

Applications
Designed to seal openings in new and existing raised floor

(Minimum QTY 10 – Sold in Multiples of 10)

TO PURCHASE ONLINE:

Buy This item Here
  • Description
  • Features
  • Additional information

Description

Airflow management devices that seal cable openings

Features

  • Reduces the need to purchase additional cooling units
  • Improves equipment reliability & extends equipment life
  • The static-dissipation feature integrates with the raised floor static dissipation system, providing 1 GigaOhm of resistance
  • Floor mounting system: Standard self-tapping screws or custom adhesive mounting kit
  • Made with fire-rated resin and filaments that meet UL94 V0 standards
  • New patented Hybrid Brush Technology (HBT) offers exceptional sealing and airflow management, unsur-passed by other leading brush products on the market today
  • Impact resistent and durable
  • Contains no loose or partially fastened parts that can become separated or fall through the raised floor
  • Satisfies NFPA 75 Section 5-4.4 requirement by self-dressing the raw metal edges of raised-floor tile cable openings
  • Compliant with the directive that restricts the use of certain hazardous substances in electrical and electronic equipment (RoHS)

Additional information

Weight 3 lbs
Dimensions 6 × 6 × 3 in

Address

4606 Appliance Drive, Belcamp, MD 21017

Phone

Phone (Toll Free) 866-740-2121
Fax (Toll Free) 866-550-1135

Email

DataCenterSales@armstrongceilings.com

Looking for a Quote or Product Support?

Please provide us with the following information and a representative will reach out to you to discuss your data center needs. 


    About Us

    4606 Appliance Drive
    Belcamp, MD 21017

    Phone (Toll Free) 866-740-2121
    Fax (Toll Free) 866-550-1135

    Email DataCenterSales@armstrongceilings.com

    PRODUCTS

    • Cooling Optimization
    • Aisle Containment
    • Power Management
    • Data Center Monitoring
    • Server Rack Infrastructure
    • Data Center Flooring
    • Modular Infrastructure
    • Cooling Optimization
    • Aisle Containment
    • Power Management
    • Data Center Monitoring
    • Server Rack Infrastructure
    • Data Center Flooring
    • Modular Infrastructure

    Support

    • Services
    • News
    • About Us
    • Contact Us
    • Services
    • News
    • About Us
    • Contact Us

    Contact

    • Privacy Policy
    • Terms and Conditions
    • Do Not Sell or Share My Info